English
 

A Waste Water Treatment Solution with two Tanks for up to 53 Residents

WSB® clean basic also brings year-round optimal cleaning performance for communities of 25 to 53 residents. Of course with all the advantages of the WSB® clean technology.


WSB® clean basic: A Waste Water Treatment Solution with two Tanks for up to 53 Residents
WSB® clean basic for 25 to 53 Residents (RE)
RE type 3 – chamber tank according to
DIN 4034, Part 2
3 – chamber tank according to
DIN 4034, Part 2
Inlet and outlet depths
    Water 
depth
prelim-
inary
clarifi-
cation
in m
Inner
dia-
meter
in m
Outer dia-
meter in m
Install-
ation depth in m
Water depth biology in m Inner
dia-
meter
in m
Outer dia-
meter in m
Install-
ation depth in m
RSZL (1) in m RSAL (2) in m
25 25K 1,50 2,50 2,80 2,75 1,45 2,50 2,80 2,75 0,87 1,20
30 30K 1,75 2,50 2,80 3,00 1,45 2,50 2,80 2,75 0,87 1,20
35 35K 2,00 2,50 2,80 3,25 1,45 2,50 2,80 2,75 0,87 1,20
40 40K 2,25 2,50 2,80 3,50 1,45 2,50 2,80 2,75 0,87 1,20
45 45K 2,50 2,50 2,80 3,75 1,45 2,50 2,80 2,75 0,87 1,20
50 50K 2,75 2,50 2,80 4,00 1,70 2,50 2,80 3,00 0,87 1,20
53 53K 3,00 2,50 2,80 4,25 1,70 2,50 2,80 3,00 0,87 1,20
(1) RSZL
Invert inlet; corresponds to inlet height measured from top edge of guard rail to invert inlet
(2) RSAL
Invert run-off; corresponds to run-off height measured from top edge of guard rail to invert run-off